Completed AC-DC Hermetic PV switchgear / box - Production - PVGroup.pl

 

Hermetic AC-DC switchgear / PV box ready

 

 

PV AC-DC switchgear

 

 

Information: Completed AC-DC encapsulated switchgear / PV box

 

The PVGroup.pl junction box is a combination of devices from different manufacturers, intended for use in isolated and grounded photovoltaic installations. Different amounts of photovoltaic strings can be connected to the PVGroup.pl junction box, depending on the version that has been selected. The box with its components may only be used in accordance with the instructions contained in this manual. Introducing changes and using third-party products and components is allowed only if they are recommended or approved by PVGroup.pl.
After completing the installation of the junction box in the existing system/installation, it is necessary to inspect and assess the risk associated with the operation of the components. Failure-free and safe operation of the junction box components can only be guaranteed if it is properly transported, stored, positioned, assembled, installed, commissioned, operated and maintained. Do not exceed the permissible ambient conditions. Observe the instructions in the accompanying documentation. If they are not followed, there is a risk of electric shock or material damage.

 

Hermetic connection box AC-DC PVGroup.pl

The boxes are intended for use in photovoltaic installations with an insulated lightning protection system or without a lightning protection system,
also where a high degree of IP protection is required. Their design is suitable for surface mounting.
2 x modular chain for 2 mppt
2 x DC type 2 surge arrester
1 x type 2 AC surge arrester
1 x 3A 32-phase circuit breaker
Ready to connect
Modular version
MC4 panel connections
Protection degree IP65
Transparent door
Protection class: II
White color

ELECTRICAL AND MECHANICAL CHARACTERISTICS OF THE HOUSING

PHS 24T model
Number of modules 24
Manufactured in accordance with EN 60670-1, EN 62208
Protection degree IP65
Protection class II
Rated insulation voltage (Ui) 690 V AC, 1000 V DC
Glow rod test 650 ° C
Impact resistance IK08
Halogen-free recyclable plastic

DC OVERFLOW LIMITER APPLIED

Manufacturer / model PHOENIX / VAL-MS 1000DC-PV / 2 + V
Type 2 surge protection
The highest permanent voltage UCPV 1170 V DC
Short-circuit proof I SCPV 2000 A
Long-term ICPV operating current <20 uA
I know. load current IL 80 A
Protective conductor current IPE <= 20 uA DC
<= 250 uA AC
Standby power consumption PC <= 25 mVA
I know the fault current (8/20) of us 15 kA
Max discharge current Imax (8/20) us 40 kA
Total current discharged Itotal (8/20) us 40 kA
Protection level Up <= 3,7 kV
Residual voltage Ures <= 3,7 kV (at In)
<= 3,1 kV (at 5kA)
<= 3,5 kV (at 10kA)
<= 4 kV (at 20kA)
<= 4,6 kV (at 30kA)
<= 5 kV (at 40kA)
Response time tA <= 25ns
Insulation resistance Riso <= 5 Gigia OM (at 500 VDC)
* In case of low stock or lack of the correct product
it is replaced with a product equivalent to the manufacturer OBO with the index 5094608
OVERCURRENT BREAKER APPLIED 1
Manufacturer / model Noark / Ex9BN 3P B32
Rated current 32A; 3-phase
Number of poles 3
Characteristics of B
Manufactured in accordance with IEC / EN 60898-1
Rated short-circuit breaking capacity ICN 6kA
APPLIED AC BOILER LIMITER
Manufacturer / model Noark / Ex9UE2 12.5 3PN 275
Manufactured in accordance with EN 61643-11
Type 2 arrester type (class II, C, T2)
Insert design LN: MOV (varistor), N-PE: GDT (spark gap)
Continuous operating voltage Uc LN: 275 V AC, N-PE: 255 V AC
Frequency f 50-60Hz
Nominal discharge current In (8/20 us) LN: 20 kA per pole, N-PE: 40 kA per pole
Max. impulse current limp (10/350 us) N-PE: 12 kA per pole
Max. discharge current Imax (8/20 us) 40 kA per pole
Voltage protection level Up for current In LN: 1,4 kV, N-PE: 1,5 kV
Voltage protection level Up for Imax LN: 2 kV, N-PE: 1,5 kV
Voltage protection level Up for 5 kA (8/20 us) LN: 2 kV, N-PE: 1,5 kV
N-PR follow current extinguishing capability Ifi 100A
Temporary overvoltage Ut (withstand) LN: 5s: 335 V, N-PE: 200 ms: 1200 V
Limiter voltage for 1mA 387 - 473V
Maximum back-up with an LN fuse: max. 125 A gG, N-PE: -
Short-circuit current capability LN: 50 kA, N-PE: -

 

RABEN is responsible for the safety of pallet shipments:

 

 

 

 

Our photovoltaic construction kits travel to you with insured transport. Shipments are packed with great care in such a way that the goods reach their destination in an undamaged form. Packing takes place under the supervision of cameras. However, if there is a problem, please write down a protocol with the courier, mark what exactly is damaged and this is where the customer's responsibility ends. PVGroup.pl sent new goods. You can find the shipping rules here.

 

Installation of the PVGroup.pl junction box

 

- Before proceeding with installation, always check the junction box for any external signs of damage. A damaged junction box must not be used.
- The place where the junction box will be installed should always be in the shade. Avoid places exposed to high temperatures, e.g. as a result of direct sunlight.

- The junction box must be installed in an area that is protected against wind and weather. Sufficient protection should be provided against moisture, snow and storms. - The junction box should be installed under the roof.
- The junction box must always be installed vertically.
- Do not install the junction box upside down.
- Sufficient air circulation must be ensured around the box housing. For this purpose, a sufficient distance of 200mm should be kept on each side, e.g. from metal covers protecting against unfavorable weather conditions and sunlight.

3.1 Mounting the housing

Along with the finished product, all the accessories necessary for installation and operation are included. Only these parts should be used.

Mounting method:
1. Pay attention to the distances of the holes in the housing
2. Mark the drilling locations on the wall.
3. Drill holes in the marked places.
4. Place appropriate dowels in the holes.
5. Loosen the four cover screws and remove the cover.
6. Screw on the generator connection box using the appropriate screws and, if necessary, washers, which are supplied with the box.
7. Tighten the main cover with a torque of 1,2 Nm to ensure an IP65 seal.

 

 

A few more details can be found in the links below:

Photovoltaic questions and answers click here.

Step-by-step instructions for your own photovoltaic installation and documentation click here.

Photovoltaic installation efficiency tests conducted by PVGroup.pl and Growatt link here

 

Contact: info@pvgroup.pl, phone +48 516 758 217, + 48 737 185 830, + 48 532 268 607

 

Complete AC-DC Hermetic PV switchgear / box: Certificates, Warranty and diagram of the PV connection switchgear:

 

  1. PVGroup.pl User manual for the PV junction box - Production PVGroup.pl
  2. Terms of the_guarantee_of production distribution districts of PVGroup.pl
  3. PVGroup.pl electrical cables catalog card for photovoltaic installations
  4. PVGroup.pl Electrical diagram of the PV AC-DC junction box

 

 

 

Weight 1 kg